<?xml version="1.0" encoding="iso-8859-1" standalone="no"?>
<!DOCTYPE GmsArticle SYSTEM "http://www.egms.de/dtd/2.0.34/GmsArticle.dtd">
<GmsArticle xmlns:xlink="http://www.w3.org/1999/xlink">
  <MetaData>
    <Identifier>26doc095</Identifier>
    <IdentifierDoi>10.3205/26doc095</IdentifierDoi>
    <IdentifierUrn>urn:nbn:de:0183-26doc0951</IdentifierUrn>
    <ArticleType>Meeting Abstract</ArticleType>
    <TitleGroup>
      <Title language="de">Intraoperative und postoperative Komplikationen von SMILE Pro (VisuMax 800): Fr&#252;he und sp&#228;te Ergebnisse</Title>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>Beckers</Lastname>
          <LastnameHeading>Beckers</LastnameHeading>
          <Firstname>David</Firstname>
          <Initials>D</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Precise Vision Augen&#228;rzte, Rheine</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Beckers</Lastname>
          <LastnameHeading>Beckers</LastnameHeading>
          <Firstname>Lena</Firstname>
          <Initials>L</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Precise Vision Augen&#228;rzte, Rheine</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Kretz</Lastname>
          <LastnameHeading>Kretz</LastnameHeading>
          <Firstname>Florian</Firstname>
          <Initials>F</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Precise Vision Augen&#228;rzte, Rheine</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Klabe</Lastname>
          <LastnameHeading>Klabe</LastnameHeading>
          <Firstname>Karsten</Firstname>
          <Initials>K</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Breyer Kaymak Klabe Augenchirurgie, D&#252;sseldorf</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Kirca</Lastname>
          <LastnameHeading>Kirca</LastnameHeading>
          <Firstname>M&#252;cella</Firstname>
          <Initials>M</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Breyer Kaymak Klabe Augenchirurgie, D&#252;sseldorf</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Kaymak</Lastname>
          <LastnameHeading>Kaymak</LastnameHeading>
          <Firstname>Hakan</Firstname>
          <Initials>H</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Breyer Kaymak Klabe Augenchirurgie, D&#252;sseldorf</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Saad</Lastname>
          <LastnameHeading>Saad</LastnameHeading>
          <Firstname>Amr</Firstname>
          <Initials>A</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Augenklinik Z&#252;rich Stadtspital, Z&#252;rich, Schweiz</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Auffarth</Lastname>
          <LastnameHeading>Auffarth</LastnameHeading>
          <Firstname>Gerd</Firstname>
          <Initials>G</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Universit&#228;tsaugenklinik Heidelberg, Heidelberg</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Breyer</Lastname>
          <LastnameHeading>Breyer</LastnameHeading>
          <Firstname>Detlev</Firstname>
          <Initials>D</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Breyer Kaymak Klabe Augenchirurgie, D&#252;sseldorf</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
    </SubjectGroup>
    <DatePublishedList>
      <DatePublished>20260617</DatePublished>
    </DatePublishedList>
    <Language>germ</Language>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Meeting>
        <MeetingId>M0651</MeetingId>
        <MeetingSequence>095</MeetingSequence>
        <MeetingName></MeetingName>
        <MeetingTitle>38. Internationaler Kongress der Deutschen Ophthalmochirurgie (DOC)</MeetingTitle>
        <MeetingSession>Refraktive Chirurgie II</MeetingSession>
        <MeetingCity>N&#252;rnberg</MeetingCity>
        <MeetingDate>
          <DateFrom>20260618</DateFrom>
          <DateTo>20260620</DateTo>
        </MeetingDate>
      </Meeting>
    </SourceGroup>
    <ArticleNo>FP 9.3</ArticleNo>
  </MetaData>
  <OrigData>
    <TextBlock name="Text" linked="yes">
      <MainHeadline>Text</MainHeadline><Pgraph><Mark1>Zielsetzung:</Mark1> Darstellung der intraoperativen Sicherheit und der postoperativen Komplikationen nach Small Incision Lenticule Extraction mit der 2-MHz-Femtosekundenplattform (SMILE Pro; VisuMax 800) im Routineeinsatz mit der ersten weltweiten kommerziellen Anwendung. </Pgraph><Pgraph><Mark1>Methode:</Mark1> Retrospektive konsekutive Fallserie in einem einzelnen Zentrum. Es wurden alle geplanten SMILE-Pro-Prozeduren analysiert (916 Augen von 482 Patienten). Die untersuchten Endpunkte umfassten die Durchf&#252;hrungsrate, intraoperative Ereignisse, postoperative Komplikationen stratifiziert nach &#60;3 und &#62;3 Monaten sowie die Rate an Nachbehandlungen.</Pgraph><Pgraph><Mark1>Ergebnis:</Mark1> Das durchschnittliche Alter betrug 32,9 &#177; 6,9 Jahre. Die mittlere pr&#228;operative Refraktion lag bei -3,60 &#177; 1,90&#47;-0,87 &#177; 0,76 dpt (Sph&#228;re&#47;Zylinder) mit einer bestkorrigierten Sehsch&#228;rfe von -0,08 &#177; 0,07 logMAR. Die Prozeduren wurden in 911&#47;916 Augen (99,45&#37;) abgeschlossen. Saugverlust trat in 6 Augen (0,66&#37;) auf; eines wurde nach erneutem Andocken komplettiert, vier wurden konvertiert (zwei ICL, zwei Femtosekunden-LASIK), und ein Auge erhielt keinen zweiten Eingriff. Es traten keine fehlgeschlagenen Lentikelpr&#228;parationen auf. Nachbehandlungen wurden in 14 Augen (1,54&#37;) durchgef&#252;hrt: 11 Re-LASIK, zwei ICL und eine Kataraktoperation. Fr&#252;he postoperative Ereignisse (&#60;3 Monate) waren vorwiegend oberfl&#228;chliche punktf&#246;rmige Keratitiden (3,51&#37;) und mildes trockenes Auge (1,32&#37;); nach mehr als 3 Monaten blieben Ereignisse selten (mildes trockenes Auge 1,65&#37;, Photopsien&#47;Halos&#47;Glare 0,88&#37;, ohne Einschr&#228;nkung der Fahrtauglichkeit bei Nacht). Schwere oder die Sehf&#228;higkeit bedrohende Komplikationen wurden nicht beobachtet.</Pgraph><Pgraph><Mark1>Schlussfolgerung:</Mark1> SMILE Pro mit dem VisuMax 800 zeigte eine hohe Durchf&#252;hrungsrate, seltene intraoperative St&#246;rungen, eine niedrige Rate an Nachbehandlungen und seltene, &#252;berwiegend milde postoperative Ereignisse. Trockenes Auge oder Photopsien entsprachen der Normalbev&#246;lkerung und zeigten keine erh&#246;hte Inzidenz. Diese Ergebnisse sprechen f&#252;r ein g&#252;nstiges Sicherheitsprofil im Routineeinsatz; ein l&#228;ngerfristiges Follow-up ist w&#252;nschenswert.</Pgraph></TextBlock>
    <Media>
      <Tables>
        <NoOfTables>0</NoOfTables>
      </Tables>
      <Figures>
        <NoOfPictures>0</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>