<?xml version="1.0" encoding="iso-8859-1" standalone="no"?>
<!DOCTYPE GmsArticle SYSTEM "http://www.egms.de/dtd/2.0.34/GmsArticle.dtd">
<GmsArticle xmlns:xlink="http://www.w3.org/1999/xlink">
  <MetaData>
    <Identifier>25dga176</Identifier>
    <IdentifierDoi>10.3205/25dga176</IdentifierDoi>
    <IdentifierUrn>urn:nbn:de:0183-25dga1762</IdentifierUrn>
    <ArticleType>Meeting Abstract</ArticleType>
    <TitleGroup>
      <Title language="en">Unsere ersten Erfahrungen mit dem Otodrive System</Title>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>H&#252;bl</Lastname>
          <LastnameHeading>H&#252;bl</LastnameHeading>
          <Firstname>Claudia</Firstname>
          <Initials>C</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Universit&#228;tsklinikum St. P&#246;lten, HNO, St. P&#246;lten, &#214;sterreich</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="yes">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
    </SubjectGroup>
    <DatePublishedList>
      <DatePublished>20250318</DatePublished>
    </DatePublishedList>
    <Language>engl</Language>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Meeting>
        <MeetingId>M0607</MeetingId>
        <MeetingSequence>176</MeetingSequence>
        <MeetingCorporation>Deutsche Gesellschaft f&#252;r Audiologie e. V. und ADANO</MeetingCorporation>
        <MeetingName>27. Jahrestagung der Deutschen Gesellschaft f&#252;r Audiologie und Arbeitstagung der Arbeitsgemeinschaft Deutschsprachiger Audiologen, Neurootologen und Otologen</MeetingName>
        <MeetingTitle></MeetingTitle>
        <MeetingSession>Postersession</MeetingSession>
        <MeetingCity>G&#246;ttingen</MeetingCity>
        <MeetingDate>
          <DateFrom>20250319</DateFrom>
          <DateTo>20250321</DateTo>
        </MeetingDate>
      </Meeting>
    </SourceGroup>
    <ArticleNo>176</ArticleNo>
  </MetaData>
  <OrigData>
    <TextBlock name="Text" linked="yes">
      <MainHeadline>Text</MainHeadline><Pgraph>The Otodrive system is an innovative motorized technology designed to assist in the cochlear electrode insertion process, promoting hearing preservation through controlled, precise, and slow-paced insertions. The system allows for an insertion time of up to 4 minutes, facilitating a steady pace critical for minimizing intracochlear trauma. Surgeons control the motorized insertion via a foot switch, while the device&#8217;s Otoarm component ensures optimal angulation and alignment with the cochlear round window. Manual placement of the electrode into the system&#39;s forceps precedes the motorized insertion phase.</Pgraph><Pgraph>To date, the Otodrive system has been utilized in 7 patient cases, executed by three surgeons. Hearing preservation was achieved in 3 patients, with the study group demonstrating an average post-operative bone conduction hearing loss of 10.8 dB. Key observations from this initial experience highlight the importance of mastering the system&#34;s forceps and aligners, which require significant practice due to the lack of tactile feedback. Additionally, while the slow insertion speed supports hearing preservation, this factor alone does not ensure optimal outcomes. Manual guidance of the electrode during insertion introduces a degree of variability, and careful removal of the forceps post-insertion is critical to avoid perilymphatic disturbance and potential damage to cochlear hair cells.</Pgraph><Pgraph>These findings underscore the potential of the Otodrive system in advancing cochlear implantation techniques while emphasizing the need for refinement in system design and surgical technique to further enhance safety and efficacy.</Pgraph></TextBlock>
    <Media>
      <Tables>
        <NoOfTables>0</NoOfTables>
      </Tables>
      <Figures>
        <NoOfPictures>0</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>