<?xml version="1.0" encoding="iso-8859-1" standalone="no"?>
<!DOCTYPE GmsArticle SYSTEM "http://www.egms.de/dtd/2.0.34/GmsArticle.dtd">
<GmsArticle xmlns:xlink="http://www.w3.org/1999/xlink">
  <MetaData>
    <Identifier>25dkou449</Identifier>
    <IdentifierDoi>10.3205/25dkou449</IdentifierDoi>
    <IdentifierUrn>urn:nbn:de:0183-25dkou4496</IdentifierUrn>
    <ArticleType>Meeting Abstract</ArticleType>
    <TitleGroup>
      <Title language="en">Biomechanical stability optimization in preoperative planning for tibal plateau fractures</Title>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>Sommerhalder</Lastname>
          <LastnameHeading>Sommerhalder</LastnameHeading>
          <Firstname>Lea</Firstname>
          <Initials>L</Initials>
        </PersonNames>
        <Address>
          <Affiliation>CustomSurg AG, Z&#252;rich, Schweiz</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="yes">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Comtesse</Lastname>
          <LastnameHeading>Comtesse</LastnameHeading>
          <Firstname>Simon</Firstname>
          <Initials>S</Initials>
        </PersonNames>
        <Address>
          <Affiliation>ETH Z&#252;rich, Z&#252;rich, Schweiz</Affiliation>
          <Affiliation>CustomSurg AG, Z&#252;rich, Schweiz</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Zumbrunn</Lastname>
          <LastnameHeading>Zumbrunn</LastnameHeading>
          <Firstname>Thomas</Firstname>
          <Initials>T</Initials>
        </PersonNames>
        <Address>
          <Affiliation>CustomSurg AG, Z&#252;rich, Schweiz</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Zamboni</Lastname>
          <LastnameHeading>Zamboni</LastnameHeading>
          <Firstname>Lara</Firstname>
          <Initials>L</Initials>
        </PersonNames>
        <Address>
          <Affiliation>CustomSurg AG, Z&#252;rich, Schweiz</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>von Keudell</Lastname>
          <LastnameHeading>von Keudell</LastnameHeading>
          <Firstname>Arvind</Firstname>
          <Initials>A</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Brigham and Women&#8217;s Hospital, Harvard Medical School, Boston, USA</Affiliation>
          <Affiliation>Bispebjerg Hospital, Kopenhagen, D&#228;nemark</Affiliation>
          <Affiliation>CustomSurg AG, Z&#252;rich, Schweiz</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
    </SubjectGroup>
    <DatePublishedList>
      <DatePublished>20251031</DatePublished>
    </DatePublishedList>
    <Language>engl</Language>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Meeting>
        <MeetingId>M0634</MeetingId>
        <MeetingSequence>449</MeetingSequence>
        <MeetingCorporation>Deutsche Gesellschaft f&#252;r Orthop&#228;die und Unfallchirurgie</MeetingCorporation>
        <MeetingCorporation>Deutsche Gesellschaft f&#252;r Orthop&#228;die und Orthop&#228;dische Chirurgie</MeetingCorporation>
        <MeetingCorporation>Deutsche Gesellschaft f&#252;r Unfallchirurgie</MeetingCorporation>
        <MeetingCorporation>Berufsverband f&#252;r Orthop&#228;die und Unfallchirurgie</MeetingCorporation>
        <MeetingName></MeetingName>
        <MeetingTitle>Deutscher Kongress f&#252;r Orthop&#228;die und Unfallchirurgie (DKOU 2025)</MeetingTitle>
        <MeetingSession>Abstracts &#124; Digitalisierung 1</MeetingSession>
        <MeetingCity>Berlin</MeetingCity>
        <MeetingDate>
          <DateFrom>20251028</DateFrom>
          <DateTo>20251031</DateTo>
        </MeetingDate>
      </Meeting>
    </SourceGroup>
    <ArticleNo>AB70-4383</ArticleNo>
  </MetaData>
  <OrigData>
    <TextBlock name="Text" linked="yes">
      <MainHeadline>Text</MainHeadline><Pgraph><Mark1>Objectives and questions: </Mark1>Complex tibial plateau fractures pose significant challenges in orthopedic surgery due to their intricate nature and potential complications &#91;1&#93;. Plate and screw fixation is a common surgical approach, but the optimal positioning of plates and screws remains a topic of debate.</Pgraph><Pgraph>Finite Element Modelling (FEM) provides a quantitative method for evaluating the biomechanical performance of various osteosynthesis constructs under physiological loading conditions &#91;2&#93;.</Pgraph><Pgraph>This study aims to improve conventional preoperative planning by using FEM as a measure for assessing and optimizing biomechanical performance. It is hypothesized that optimized osteosynthesis configurations provide greater stability than standard approaches.</Pgraph><Pgraph><Mark1>Material and methods: </Mark1>Schatzker IV fractures with lateral depression were induced in six left human lower extremity cadaveric specimens (Rimasys, Germany). They underwent a computed tomography (CT) scan, after which the proximal tibia fragments were segmented and realigned to achieve anatomic fracture reduction. </Pgraph><Pgraph>All fracture fixations were planned with a medial variable angle locking plate (Pangea, Stryker, Switzerland). Initial implant configurations were based on standard surgical planning by a fellowship trained surgeon. Then, each case underwent an iterative process to optimize plate and screw positions by means of FEM. To evaluate the stability of the osteosynthesis constructs, initial and final configurations were biomechanically simulated using Abaqus (Simulia, Dassault Syst&#232;mes, France). Knee joint reaction forces were scaled according to patient weight and patient-specific Hounsfield-Unit-derived bone material properties were applied to the 3D model.</Pgraph><Pgraph><Mark1>Results: </Mark1>The mean maximal displacement magnitude for the initial surgeon configuration was 1.17 mm (<Mark2>SD</Mark2> &#61; 0.43 mm) while in the optimized configuration, it was 0.66 mm (<Mark2>SD</Mark2> &#61; 0.19 mm) which corresponds to a mean relative reduction of 39.25&#37;. This represents a significant reduction in maximal displacement (<Mark2>p</Mark2> &#61; 0.01) achieved with no significant change in number of screws used (<Mark2>MInitial</Mark2> &#61; 11, <Mark2>SD</Mark2> &#61; 1.27, <Mark2>MOptimized</Mark2> &#61; 11, <Mark2>SD</Mark2> &#61; 0.89, <Mark2>p</Mark2> &#61; 0.50).</Pgraph><Pgraph><Mark1>Discussion and conclusions: </Mark1>Optimizing plate and screw positioning significantly reduced displacement compared to conventional planning, especially in initially unstable constructs.</Pgraph><Pgraph>The improvement in stability was particularly pronounced in constructs where the initial configuration showed large displacements.</Pgraph><Pgraph>Hence, patient-specific FEM provides valuable insights into how plate positioning affects fracture stability, which may guide orthopedic surgeons towards optimized plate placement strategies.</Pgraph><Pgraph>Figure 1 <ImgLink imgNo="1" imgType="figure" /></Pgraph></TextBlock>
    <Media>
      <Tables>
        <NoOfTables>0</NoOfTables>
      </Tables>
      <Figures>
        <Figure width="690" height="572" format="png">
          <MediaNo>1</MediaNo>
          <MediaID>1</MediaID>
          <Caption><Pgraph><Mark1>Figure 1</Mark1></Pgraph></Caption>
        </Figure>
        <NoOfPictures>1</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>